1080

Stripper 1080

HumiSeal® Stripper 1080 is:

  • compatible with all HumiSeal acrylic coatings.
  • compliant with RoHS directive 2015/863/EU
  • safe for use on printed circuit board assemblies.

Stripper 1080 has:

  • no ozone depleting chemicals

Directions for Use

  1. immerse the assembly into HumiSeal® Stripper 1080
  2. soak for 30-60 minutes
  3. brush loose material from the assembly
  4. clean the assembly with IPA, DI water or other qualified cleaning solution
  5. inspect the assembly to ensure the coating has been completely removed
  6. repeat the steps above if the coating is still on the assembly
  7. bake for a minimum of 30 minutes @ 60 – 65°C after the final cleaning process

The use of heat is not required for use with HumiSeal® Stripper 1080. A fully cured acrylic coating of nominal thickness will typically dissolve readily within 30 to 60 minutes upon contact with HumiSeal® Stripper 1080. It is important to thoroughly clean the assembly after the conformal coating removal process. Following the cleaning process, the assembly should be baked to remove residual moisture for a minimum of 30 minutes at 60 – 65°C.

Handling Precautions

  • Use only in well-ventilated areas.
  • Protective gloves and goggles should be worn.
  • In case of prolonged skin contact, wash with water.
  • In case of eye contact, flush with plenty amount of water and contact physician.
  • Avoid prolonged breathing of vapors.
  • Unused portions of HumiSeal® products must be disposed of in compliance with all applicable environmental regulations.
  • Consult the Safety Data Sheet (SDS) for more specific product information.
Product Specification
Compatible HumiSeal® Coatings HumiSeal® Solvent-Based Acrylics
Relative Evaporating Rate (BuAc=1) 1.0
Specific Gravity 1.3 ± .02
Flash Point (°C) TCC 21.7
Shelf Life, DOM 18 months
Color Clear to Reddish

Other products in this chemistry include:


To view SDS files you need to Login or Request Access.

Contact Us