Thinner
Thinner 903 is:
- Compatible with HumiSeal 1B51NSLU
- RoHS directive 2015/863/EU
Thinner 903 has:
- flammable ingredients
Directions for Use
Add HumiSeal® Thinner to a compatible coating until the desired viscosity is obtained.
Handling Precautions
HumiSeal® Thinners are flammable and the following standard safety precautions should be observed:
- Use only in well-ventilated areas.
- Protective gloves and goggles should be worn.
- In case of prolonged skin contact, wash with water.
- In case of eye contact, flush with water and contact physician.
- Avoid prolonged breathing of vapors.
- Unused portions of HumiSeal® products must be disposed of in strict compliance with Local, State, and Federal laws governing such matters.
- Consult the Material Safety Data Sheet (MSDS/SDS) for more specific product information.
Product Specification | |
Compatible Coatings | 1B51NSLU |
Relative Evaporating Rate (BuAc =1) | >1 |
Specific Gravity | 0.78 ± 0.01 |
Boiling Point (°C) | 115 |
Vapor Pressure (mmHg) | 34.0 |
Vapor Density (Air=1) | 3.7 |
Flash Point (°C) | -1 |
VOC (grams/litre) | 775 |
Shelf Life (DOM) | 24 months |
Colour | Clear |