1R32A-2

HumiSeal® 1R32A-2 conformal coating is:

  • a fast drying
  • single component acrylic coating
  • formulated for improved adhesion to typical substrates while providing excellent moisture and environmental protection for printed circuit assemblies.
  • fluoresces under UV light for ease of inspection and is easily repaired.

HumiSeal® 1R32A-2 conformal coating has:

  • IPC-CC-830 compliance
  • RoHS directive 2015/863/EU
  • UL File Number E105698.

button (1)                                     SDS Request

Cleanliness of the substrate is of extreme importance for the successful application of a conformal coating. Surfaces must be free of moisture, dirt, wax, grease, flux residues and all other contaminants. Contamination under the coating could cause problems that may lead to assembly failures.

Dipping
Depending on the complexity, density and configuration of components on the assembly, it may be necessary to reduce the viscosity of HumiSeal® 1R32A-2 with HumiSeal® Thinner 503 or 505 in order to obtain a uniform film. Once optimum viscosity is determined, a controlled rate of immersion and withdrawal (5-15 cm/min) will further ensure even deposition of the coating and ultimately a uniform film. During the application, evaporation of solvent causes an increase in viscosity that should be adjusted by adding small amounts of HumiSeal® Thinner 503 or 505. Viscosity in the dip tank should be checked regularly using a simple measuring device such as a Zahn or Ford viscosity cup.

Spraying
HumiSeal® 1R32A-2 can be sprayed using conventional spraying equipment. Spraying should be done in an environment with adequate ventilation so that the vapour and mist are carried away from the operator. The addition of HumiSeal® Thinner 521, 521EU or 600 is necessary to ensure a uniform spray pattern resulting in pinhole-free film. The amount of thinner and spray pressure will depend on the specific type of spray equipment used and operator technique. The recommended ratio of HumiSeal® 1R32A-2 to HumiSeal® Thinner 521, 521EU or 600 is 1:1 by volume; however the ratio may need to be adjusted to obtain a uniform coating.

Brushing
HumiSeal® 1R32A-2 may be brushed with a small addition of HumiSeal® Thinner 503 or 505. Uniformity of the film depends on component density and operator’s technique.

Product Specification
Density, per ASTM D1475 0.91 ± 0.02 g/cm³
Solids Content, % by weight per Fed-Std-141, Meth. 4044 29 ± 3 %
Viscosity, per Fed-Std-141, Meth. 4287 220 ± 30 centipoise
VOC 645 grams/litre
Drying Time to Handle per Fed-Std-141, Meth. 4061 10 minutes
Recommended Coating Thickness 25 – 75 microns
Recommended Curing Conditions 24 hrs @ RT or 30 min @ 76°C
Time Required to Reach Optimum Properties 7 days
Recommended Thinner (dipping & brushing) HumiSeal Thinner 503, 505
Recommended Thinner (spraying) HumiSeal Thinner 521, 521EU, 600
Recommended Stripper HumiSeal Stripper 1080, 1080EU
Shelf Life at Room Temperature, DOM 24 months
Thermal Shock, 50 cycles per MIL-I-46058C -65°C to 125°C
Coefficient of Thermal Expansion – TMA 170 ppm/°C below Tg

340 ppm/°C above Tg

Glass Transition Temperature – DSC 14°C
Modulus – DMA 2000 MPa @ -40°C

1050 MPa @ 20°C

8.5 MPa @ 60°C

Flammability, per UL 94 V-0
Dielectric Withstand Voltage, per MIL-I-46058C >1500 volts
Dielectric Breakdown Voltage, per ASTM D149 7500 volts
Dielectric Constant, at 1MHz and 25°C per ASTM D150-98 2.5
Dissipation Factor, at 1MHz and 25°C, per ASTM D150-98 0.01
Insulation Resistance, per MIL-I-46058C 8.0 x 1014 ohms (800TΩ)
Moisture Insulation Resistance, per MIL-I-46058C 6.0 x 1010 ohms (60GΩ)
Fungus Resistance, per ASTM G21 Passes