Vivid Cure™ 806-UVA
LOW STRESS, LIQUID OPTICALLY CLEAR ADHESIVE (LOCA)
Fast curing, water-white clear, urethane acrylate designed for utilization as an LCD interface adhesive. This product is a soft, flexible, low modulus polymer that provides a high amount of bond strength without imparting stress. This is a non-yellowing adhesive that exhibits excellent resistance to moisture.
APPLICATIONS | FEATURES | SUBSTRATES |
Touch Screen Display | RoHS & REACH Compliant | Plastics |
LCD | GB 33372-2020 Compliant | Glass |
Large Format Displays | Non-Yellowing, No-Haze | Metals |
Consumer Displays | Low-Stress Adhesive | |
Medical Devices | Ultra-Low Shrinkage | |
UVA Curable |
Typical Properties of HumiSeal® Vivid CureTM 806-UVA
Chemical Class | UV Acrylate |
Appearance | Clear |
Viscosity @ 25°C, Spindle 5 @ 20 RPM, cps | 1,900 to 3,100 |
Specific Gravity | 0.87-0.93 |
Cleanup Solvent | Isopropyl alcohol |
UV Curing Guidelines*
HumiSeal Vivid Cure™806-UVA adhesive has been formulated to allow flexibility in the curing process. HumiSeal Vivid Cure™ 806-UVA can be cured using full spectrum mercury vapor light systems as well as 365nm and 395nm LED systems. The table below details minimum dosage values required to properly crosslink HumiSeal Vivid Cure™ 806-UVA.
Due to the spectral output differences emitted between LED and mercury vapor systems, wavelength-specific minimum requirements will vary. 365nm is the preferred wavelength due to its efficiency in crosslinking the HumiSeal Vivid Cure™806-UVA.
“Note, adhesive thickness range of 700 – 750 microns was used during the development of the minimum required dosage values recommended below. If a different adhesive thickness is used, process adjustments may be required.”
Vivid CureTM 806-UVA Recommended Minimum Dose (J/cm2) Requirements | |
Wavelength (nm) | UVA |
365nm | 1.7 |
395nm | 1.9 |
Full Spectrum Mercury Vapor | 2.6 |
Values measured with an EIT Powerpuck II
* These values are for guidelines only and not meant to be used as a specification
It is recommended that you contact HumiSeal technical support to discuss your application and review the required recommended minimum cure requirements.
Typical Properties of Cured Material** | |
Tensile Modulus @ -60°C, MPa | 100 to 500 |
Glass Transition Temperature (Tg), °C | -40 to -45 |
Linear Shrinkage, % | < 1 |
Refractive Index | 1.459 to 1.470 |
Haze, %, per ASTM D1003 | < 0.2 |
Total Luminous Transmittance, %, per ASTM D1003 | > 99 |
Color Coordinate, b* | 0.03 |
Dielectric Constant / Dissipation Factor @ 200 KHz | 2.94 / 0.045 |
Dielectric Constant / Dissipation Factor @ 400 KHz | 2.65 / 0.044 |
Dielectric Constant / Dissipation Factor @ 800 KHz | 2.86 / 0.042 |
Dielectric Constant / Dissipation Factor @ 1 MHz | 2.79 / 0.046 |
Operating Temperature Range, °C | -50 to 125 |
**All properties given are typical values and are not intended for use in preparing specifications.
Storage & Handling
HumiSeal Vivid Cure™ 806-UVA should be stored between 8°C – 28°C in tightly closed, light-blocking containers, away from direct sunlight. Keep from freezing. Allow material to equilibrate to process area temperature for 24 hours before use. Please refer to product labeling for shelf-life information. While the material can be heated to facilitate degassing prior to use, this operation should be conducted only on the amount of adhesive to be immediately used. Multiple heating cycles of the bulk container or elevated temperature storage of HumiSeal Vivid Cure™ 806-UVA should be avoided. Consult SDS for full safety information.
*Values measured with a Powerpuck II UV radiometer